Error Code: F2 - The Indoor Ambient Temperature Sensor Fault

When the error code 'F2' appears you can do the following to fix the problem: 

  • Check whether the resistance of sensor is normal, otherwise replace it.
  • Check whether the sensor wire is short circuit or open circuit, and whether the plug is well contacted, whether there is welding off or rosin joint on the electric control board. If any of the following is true, you'd need to repair it. If you need further help, contact us via email at info@airconditioningcentre.com or call us at 0370 3344 556. 
  • After checking everything (above) and you still cannot figure out the problem, then the components or integrated circuit is damaged. This means the electric control board should be replaced. 

To purchase any spare parts - like a new electric control board - call us at 0370 3344 556 or email us at info@airconditioningcentre.com.

 

  • 77 Users Found This Useful
Was this answer helpful?

Related Articles

Error Code: F9 - The Compressor Discharge Temperature Sensor Fault

When the error code 'F9' appears, you can do the following to fix the problem:  Check whether...

Error Code: F1 - Communication Fault

When the error code 'F1' appears you can do the following  to fix the problem:  Check whether...

Error Code: F3 - The Coil Pipe Temperature Sensor Of Indoor Unit Fault

If the error code 'F3' appears, you can do the following to try and fix the problem:  Check...

Error Code: F4 - Indoor Fan Fault

When the error code 'F4' appears you can do the following to try and fix the problem:  Check...

Error Code: F5 - Module of Outdoor Unit Fault

When the error code 'F5' appears you can do the following to fix the problem:  Check whether...