Error Code: FF - Outdoor DC fan fault

When the error code 'FF' appears you can do the following to fix the problem: 

  • Check if the compressor runs for 1 minute and the outdoor fan does not start, this means there is a fault with the outdoor fan motor
  • Check if the compressor and fan run for 1 minute and then shuts down, this means there is fault with the 4 way valve. Check the solenoid is connected to the PCB properly. Does the unit operate in the other mode, if so then the valve is faulty. 
  • Check the outdoor PCB for damage, if there are any burn marks then the PCB needs replacing. 

note: commonly this error signifies the system is low on refrigerant. An engineer is needed to check for leaks and recharge the system. 

If you want to purchase any new parts for your unit or any further help, contact us via email at info@airconditioningcentre.com or call us at 0370 3344 556. 

  • 4 A felhasználók hasznosnak találták ezt
Hasznosnak találta ezt a választ?

Kapcsolódó cikkek

Error Code: F9 - The Compressor Discharge Temperature Sensor Fault

When the error code 'F9' appears, you can do the following to fix the problem:  Check whether...

Error Code: F1 - Communication Fault

When the error code 'F1' appears you can do the following  to fix the problem:  Check whether...

Error Code: F2 - The Indoor Ambient Temperature Sensor Fault

When the error code 'F2' appears you can do the following to fix the problem:  Check whether...

Error Code: F3 - The Coil Pipe Temperature Sensor Of Indoor Unit Fault

If the error code 'F3' appears, you can do the following to try and fix the problem:  Check...

Error Code: F4 - Indoor Fan Fault

When the error code 'F4' appears you can do the following to try and fix the problem:  Check...